main-image
ImageSetByPath

282-818902

Visit Product Series:

Acme’s Pressure Temperature Control Manifolds (PTCMs) are based on the Kaye & MacDonald pilot activated Pressure and Control Valve.

Acme Indicating Pressure Switches are a combination switch and gauge used to activate alarm panels, which alert users when a cylinder or cylinder bank is empty and changeout must occur. They are available in brass or stainless steel models and are suitable for a variety of gas services. The Switches are easily set by removing the lens cover and sliding the lever located at the outside of the dial to the desired setpoint. This feature provides permanent visual setpoint verification.

Markets
Applications
Connections Inlet: Type K Copper Tube|Outlet: Type K Copper Tube
Flow Capacity 65,000 SCFH * This is the estimated flow based on 150 PSIG inlet pressure, 125 PSIG delivery pressure and nitrogen gas at 70°F
Inlet Pressure 0-400 PSIG
Max. Operating 150° F @ 400 PSIG
Max. Oxygen 250 PSIG
Min. Operating Temp. -40° F
N2, AR MAWP (ambient temp.) 400 PSIG
Outlet Pressure 15-400 PSIG (75-250 PSIG for O2 Service
Temperature Range 300° F @ 275 PSIG
Bleed Flow 1-2 SCFH
Equivalent Cv 54
Low Temperature -40° F
Material Stand: Stainless Steel|Tubing: Copper|Components: Bronze and Brass
Options Left to Right or Right to Left Configuration - - Stainless Steel|- UHP Electropolished
Product Type Industrial Manifolds
PublishedDate 1770097550847
SEO Title 282-818902 | Gas - Liquid Handling | Pressure Temperature Control Manifold
Standard Delivery 75-175 PSIG *A spring is shipped with each manifold for delivery pressures less than 75 PSIG